Limited moment type magnetic coupling device

Limited moment type magnetic coupling device

Torque-limited magnetic coupling
Working principle: The torque-type magnetic coupling is generally composed of a permanent magnet rotor and a conductor rotor. The permanent magnet rotor and the conductor rotor have a variable air gap. When the active machine drives the conductor rotor to rotate, it is opposite to the driven end. When the permanent magnet acts as a circular motion of the cutting magnetic line, the conductor rotor of the active end generates an eddy current induced magnetic field, and interacts with the permanent magnet magnetic field of the driven end, thereby achieving contactless torque transmission between the active end and the driven end. When the working machine is under rated load conditions, the air gap between the permanent magnet rotor and the conductor rotor is the smallest; when the working machine is overloaded or stuck, the air gap between the permanent magnet rotor and the conductor rotor increases rapidly until the maximum air gap, The permanent magnet rotor speed of the working machine is reduced or reaches zero, so that the overload protection of the motor is realized; when the overload or the stuck working condition is released, the position of the permanent magnet rotor and the conductor rotor is restored to the original minimum air gap by the recovery mechanism, The machine returns to normal working condition.
Features: 1. Soft start / soft brake, reduce the starting energy of the motor and avoid causing a large voltage shock to achieve real energy saving.
2. Overload protection function. When the load is overloaded or exceeds the set torque, the coupling automatically pulls the air gap to automatically disengage the motor and load; when the fault is removed, the system automatically resets to protect the motor from damage.
3. Flexible connection, smooth transmission, reducing system vibration transmission.
4. Extend the service life of each component in the transmission system.
5. Allows for large installation deviations, greatly simplifying the installation and commissioning process.
6. Maintenance, easy installation and low cost.
7. No pollution to the power grid, no harmonics.
8. It is convenient to transform the original system, and it is more suitable for the connection of the new transmission system.
9. It can run stably for a long time and has a long service life.
























































































































Limiting moment magnetic coupling selection table
specification Φ(mm) W(mm) A (mm) S(mm) L(mm) D1(mm) D2(mm) Speed (r/min) Maximum transfer power (KW)
HCOX-0005 232 161 57 161 274 42 42 3000/1500 12/5
HCOX-0010 280 186 57 186 296 48 48 3000/1500/1000/750 30/10/4/3
HCOX-0015 330 196 57 196 306 55 55 3000/1500/1000/750 58/15/6/4.5
HCOX-0040 380 223 61 223 336 60 60 3000/1500/1000/750 110/40/20/11
HCOX-0050 430 236 87 236 401 75 75 3000/1500/1000/750 135/50/25/15
HCOX-0090 480 236 87 236 401 75 75 3000/1500/1000/750 85/90/56/42
HCOX-0125 530 216 107 216 421 80 80 3000/1500/1000/750 250/125/75/58
HCOX-0160 580 216 117 216 441 100 100 3000/1500/1000/750 325/160/100/75
HCOX-0210 630 216 117 216 441 100 100 3000/1500/1000/750 425/210/132/100
HCOX-0260 680 216 117 216 441 100 100 3000/1500/1000/750 525/260/165/125